Effect of Streptomycin on Stretch-Induced Change in Myocardial Activation During Ventricular Fibrillation

Efectos de la estreptomicina en las modificaciones de la activación miocárdica durante la fibrilación ventricular inducidas por el estiramiento

Isabel TraperoaFrancisco J ChorrobLuis Such-MiquelcJoaquín CánovesdÁlvaro TormoseFrancisca PelechanofLaura LópezcLuis Suchf

Options

The aim of this study was to determine whether the changes in myocardial activation pattern resulting from acute stretching during ventricular fibrillation can be counteracted by administering a compound that blocks receptors sensitive to stretch. The study involved 16 isolated rabbit hearts, in which refractoriness and activation frequency during ventricular fibrillation were measured before, during and after localized acute stretching of the left ventricular free wall, either without (series A, n=8) or with (series B, n=8) the presence of streptomycin, 200 μmol. At baseline and during and after stretching, ventricular fibrillation was slower with streptomycin perfusion in series B than in series A (dominant frequency at baseline, 13±2 Hz vs. 16±2 Hz, respectively; P<.005; dominant frequency with stretching, 14±2 Hz vs. 19±3 Hz, respectively; P<.005). Streptomycin attenuated the electrophysiological changes produced by stretching and had a direct effect on refractoriness and activation frequency during ventricular fibrillation.

Keywords

Ventricular fibrillation
Electrophysiology
Myocardial stretch
Streptomycin

INTRODUCTION

Stretching changes the electrophysiological properties of both atrial and ventricular cardiac tissue by activating and opening stretch-sensitive channels, and causing alterations in the cellular ion currents.1 Because there is a large variety of mechanosensitive ion channels, an agent that can block all these channels has still not been identified. The aminoglycoside antibiotic streptomycin, although it is not specific, has been reported to block stretch-sensitive channels and reduce the development of arrhythmias induced by mechanical causes.2,3 Myocardial activation during ventricular fibrillation (VF) depends on electrophysiological properties, and for this reason stretching also changes the characteristics of activation during arrhythmia.4 The mechanisms producing these changes have not been clearly established, however. The present study investigates whether stretch-induced changes in the myocardial activation pattern during VF are counteracted by streptomycin.

METHODS

Experiment Preparation

The experiments were performed following the regulations set down in Spanish Royal Decree 1201/2005 of October 10, regarding the use of animals for scientific purposes.

Sixteen isolated, perfused, rabbit heart preparations were used, following previously described methods.5,6 An L-shaped device was inserted in the left ventricular cavity to produce local stretching of the left ventricular free wall (Figure 1). Recordings were obtained with 2 multiple electrodes placed in the epicardium of the left ventricle, 1 in the area submitted to local stretching (SA) and another in an unaltered area (NSA), with 121 and 119 unipolar electrodes, respectively.

Figure 1. Schematic diagram of the device used to produce local stretching, with epicardial multielectrodes in the study areas. LV (ANT) indicates anterior left ventricle; LV (PST), posterior left ventricle; SA, stretched area; NSA, nonstretched area.

Two series of experiments were performed following the same protocol (baseline-stretching-post-stretch), the only difference being the absence (series A, n=8) or presence (series B, n=8) of streptomycin (200 μmol) in the perfusion fluid of the heart since the start of the preparation.

Data Analyzed

Ventricular fibrillation was induced by overstimulation, perfusion was maintained, and the following parameters were determined in both series: the dominant frequency (DFr) during VF (Welch method5,6) (Figure 2), the interval between successive ventricular activations (VV interval), and the functional refractory period. These parameters were determined before (5-min period), during (10 min), and after (10 min) local ventricular wall stretching (longitudinal increase of 12%).

Figure 2. Power spectra of ventricular fibrillation in the altered area obtained from 1 experiment in each series at baseline and during stretching. DFr indicates dominant frequency (Hz); PSD, power spectrum density; NU, normalized units.

Statistical Calculations

The data are presented as the mean (standard deviation). Comparisons were performed using a general linear model with repeated measures, considering the phases of the experiment as a within-subject factor and the use of streptomycin or not as a between-subject factor, and applying the Bonferroni test as the post hoc test (P<.05, significant differences).

RESULTS

Effect of Streptomycin on Stretch-Induced DFr Changes

In series A, DFr was significantly increased in the SA (P=.002), but not in the NSA (general analysis, within-subject comparison test, factor phases of the experiment). Differences between the 2 heart areas were significant from minutes 2 to 6 of stretching (Figure 3).

Figure 3. Dominant frequency during ventricular fibrillation (mean [standard deviation]) obtained at 1-minute intervals in the stretched and nonstretched sreas of the heart in series A (above) and series B (below). E1 to E10 indicates stretching; DFr, dominant frequency (Hz); P1 to P10, post-stretch; SA, stretched area; NSA, nonstretched area. *SA versus NSA, P<.05.

In series B, the influence of the experiment phase factor was also significant in the SA (P=.001) and not in the NSA. Differences between the 2 areas were significant from minutes 2 to 4 of stretching.

Comparison between the 2 series showed that the DFr was lower in series B (streptomycin) than in series A in both areas of the heart (general analysis, between-subject differences: NSA, P=.027; SA, P=.016).

Effects of Streptomycin on Stretch-Induced VV Interval Changes during Ventricular Fibrillation

In series A, VV intervals in the SA were shorter during stretching with respect to baseline values (P=.04) and post-stretch values (P=.018), whereas in the NSA there were no significant changes (within-subject comparison, experiment phase factor) (Table 1).

In series B, VV intervals in the SA during stretching were also shorter relative to baseline (P=.002) and following stretching (P=.004) (within-subject comparison, experiment phase factor).

Comparison between the 2 series showed longer VV intervals in series B (streptomycin) than in series A in both heart areas (between-subject differences: NSA, P=.004; SA, P=.001).

Effects of Streptomycin on Stretch-Induced Changes in Electrophysiological Parameters

In series A, refractory periods during VF were also shorter in the SA during stretching (P=.026 vs baseline and P=.045 vs post-stretch values), whereas no changes were seen in the NSA (Table 2).

In series B, refractory periods were decreased in the SA during stretching (P=.01 vs baseline P=.001 vs post-stretch values) and the NSA showed no variations.

With the action of streptomycin (series B), values were higher in the NSA and differences did not reach statistical significance in the SA (between-subject differences: NSA, P=.047; SA, P=.075).

DISCUSSION

The main finding of this study is that streptomycin decreased the effects of myocardial stretching during VF, and had a slowing action on VF both during and in the absence of stretching. The results were obtained with high drug concentrations, well above the therapeutic dose in humans. The concentrations used were those described to avoid the changes produced by stretching.3

Garnier et al7 found that streptomycin inhibited the increased intracellular calcium concentration induced by stretching in ventricular myocytes; hence the finding of reductions in these concentrations would be one of the reasons for the decrease in stretch-induced arrhythmias in the presence of streptomycin. These authors reported that streptomycin had no effect on L-type calcium channels. Moreover, Eckard et al3 did not observe the results obtained with streptomycin when using verapamil as a specific calcium blocker, thereby demonstrating that the effects of streptomycin are produced by blocking the mechanosensitive ion channels. The present study has contributed to this research with data showing the action of streptomycin on myocardium that is not subjected to any manipulation: in addition to attenuating the effects of stretching, streptomycin had a slowing effect on VF in the absence of stretching. The electrophysiological effects inherent to streptomycin may explain the VF changes observed in the present study in the control situation, in the area that was not altered by stretching.

The capability of streptomycin to inhibit triphosphate inositol production may also be implicated in its possible antiarrhythmic effect. Du et al8 observed that different drug compounds, among them streptomycin and gentamicin, inhibit triphosphate inositol release during reperfusion, and that intravenous gentamicin can even suppress the onset of arrhythmias. This is a parallel mechanism, in which adenosine triphosphate is likely implicated.

Bauty et al9 and Sung et al10 have indicated that other mechanisms in addition to activation of stretch-sensitive channels may come into play during stretching. This fact might be related to the persistence of stretch-induced alterations in VF, despite the use of high concentrations of streptomycin.

In conclusion, streptomycin attenuated the electrophysiological changes and alterations in myocardial activation during VF produced by acute stretching and had a direct effect on the refractoriness and activation frequency.

ACKNOWLEDGEMENTS

The authors thank César Avellaneda and Camilo Gómez for their help in preparing the electrodes and stretching device, and Rosa Cibrián for performing the statistical analysis.

This study has been funded by grants from the Spanish Ministry of Health (FIS PI06/0758 and RETIC RD06/0003/0010 REDINSCOR) and the Spanish Society of Cardiology (SEC 2004).


Correspondence: Dr. F.J. Chorro Gascó.
Servicio de Cardiología. Hospital Clínico Universitario.
Avda. Blasco Ibáñez, 17. 46010 Valencia. España.
E-mail: Francisco. J. Chorro@uv.es

Received October 16, 2006.
Accepted for publication September 12, 2007.

Bibliography
[1]
Stretch-activated arrhythmias. En: Zipes DP, Jalife J, editores. Cardiac Electrophysiology: From Cell to Bedside. New York: WB Saunders; 1994. p. 597-606.
[2]
Salmon AH, Mays JL, Dalton GR, Jones JV, Levi AJ..
Effect of Streptomycin on wall-stress-induced arrythmias in the working rat heart..
Cardiovasc Res, (1997), 34 pp. 493-503
[3]
Eckardt L, Kirchhof P, Mönning G, Breithardt G, Borggrefe M, Haverkamp W..
Modification of stretch-induced shortening of repolarization by streptomycin in the isolated rabbit heart..
J Cardiovasc Pharmacol, (2000), 36 pp. 711-21
[4]
Chorro FJ, Cánoves J, Guerrero J, Mainar L, Sanchis J, Soria E, et al..
Opposite effects of myocardial stretch and verapamil on the complexity of the ventricular fibrillatory pattern: An experimental study..
Pacing Clin Electrophysiol, (2000), 23 pp. 1594-603
[5]
Chorro FJ, Trapero I, Guerrero J, Such LM, Canoves J, Mainar L, et al..
Modification of ventricular fibrillation activation patterns induced by local stretching..
J Cardiovasc Electrophysiol, (2005), 16 pp. 1087-96
[6]
Chorro FJ, Guerrero J, Trapero I, Such-Miquel L, Mainar L, Cánoves J, et al..
Análisis tiempo-frecuencia de la fibrilación ventricular. Estudio experimental..
Rev Esp Cardiol, (2006), 59 pp. 869-78
[7]
Garnier F, White E, Lacapagne A, Garnier D, Le Guennec JY..
Streptomycin reverse a large stretch induced increases in [Ca2+]i in isolated Guinea pig ventricular myocytes..
Cardiovasc Res, (1994), 28 pp. 1193-8
[8]
Du XJ, Anderson KE, Jacobsen A, Woodcok EA, Dart AM..
Supression of ventricular arrhytmias during ischemia-reperfusion by agents inhibiting Ins(1,4,5)P3 release..
Circulation, (1995), 91 pp. 2712-6
[9]
Bauty D, Lab M..
Heterogeneous changes of monophasic action potential induced by sustained stretch in atrium..
J Cardiovasc Electrophysiol, (2001), 12 pp. 323-9
[10]
Sung D, Mills RW, Schettler J, Narayan SM, Omens JH, McCulloch AD..
Ventricular filling slows epicardial conduction and increases action potential duration in an optical mapping study of the isolated rabbit heart..
J Cardiovasc Electrophysiol, (2003), 14 pp. 739-49
Are you a healthcare professional authorized to prescribe or dispense medications?